Fiso FPI-HR Module

OEM multichannel signal conditioner

Linkedin Twitter Google+

Key Features
  • High accuracy
  • Up to 15 kHz sampling rate
  • Temperature-compensated modules
  • Atmospheric pressure compensation (option)
Buy Online

We currently don't have any FPI-HR Module parts to order online. Please call +44(0)118 9769000 for further assistance

Place your order before 2pm to select next day delivery. In a hurry? pre 10:30am delivery also available.


The FPI-HR module is a high resolution part of the Evolution range designed for general temperature and pressure applications.

  • 1 or 2 channels
  • Sampling rate up to 250Hz


  Temperature - FOT-L Pressure - FOP-M
Measuring range −10 to 120°C R1: 0 to 5 psi / R2: 0 to 50 psi / R3: 0 to 150 psi / R4: 0 to 1000 psi
Temperature operating range SD: −40 to 300°C
BA: −40°C to 250°C
−20 to 150°C
Response time¹ <1.5s -
Accuracy² R4: ±0.25°C / R5: ±0.40°C ±0.5% of full scale
Resolution 0.01°C 0.05% of full scale
Sampling rate Up to 250Hz per module Up to 250Hz per module
Power consumption 5 Watts 5 Watts
Analog output (optional) 0 to 5V or 4 - 20 mA / 16 bits resolution 0 to 5V or 4 - 20 mA / 16 bits resolution
Operating temperature 10 to 50°C 10 to 50°C
Storage temperature - 30 to 80°C - 30 to 80°C
Connector SCAI³, SCA (ST optional) SCAI³, SCA (ST optional)
Fiber core size 62.5/125μm (50/125μm optional) 62.5/125μm (50/125μm optional)
Number of channel(s) 1 or 2 1 or 2
Communication/Evolution chassis USB via EVO chassis / TS 35 DIN RAIL USB via EVO chassis / TS 35 DIN RAIL
Communication/OEM RS-232 / RS-485 RS-232 / RS-485
LED sensor signal and communication diagnostic Yes Yes

¹ - Time required to reach 63% of a temperature step.

² - Includes reproducibility (sensor/module exchange), repeatability and hysteresis, non-linearity, scale error, offset error, conditioner temperature compensation error

  • Temperature:

Accuracy of ±0.25°C can be achieved using the 25°C to 45°C calibration.

Accuracy of ±0.40°C can be achieved using the −10°C to 120°C calibration.

  • Pressure:

Accuracy at room temperature.

³ - SCAI is an SCA connector with smart chip communicating calibration data to signal conditioner module.